Street · 855 of 8,567 by permit count
Building permits on Prince Arthur Ave
The City of Toronto has 213 building permits on record for Prince Arthur Ave, going back to 1994. Those permits created 1 homes and removed 0, a net change of +1. Declared construction value totals $27.2M. The most recent permit was applied for Aug 31, 2026 at 8 Prince Arthur Ave.
- Permits on record
- 2131994–2026
- Declared construction value
- $27.2Mas filed, not adjusted
- Homes created
- 1dwelling units
- Homes removed
- 0net +1
Permits issued per year
20002026 (part year)
Most common work
Structures worked on
Most recent permits
| Issued | Work | What was filed | Value | Status |
|---|---|---|---|---|
| Aug 31, 2026 | Multiple Projects | Revision 01: Proposed Interior Renovations. Updated Underpinning depths to an existing 3 Storey Commercial BuildingProposed interior alterations and underpinning (118.50 sm) | — | Open |
| Mar 13, 2026 | Multiple Projects | REVISION 2- add one room in the basement (Booth 015), revise the open waiting room 104 to an enclosed meeting room (Meeting 104) with accessible door added, revise the glazed partition at (Boardroom 105) from an operable partition, to a fixed partition with accessible doors, whereas previous mechani | — | Open |
| Mar 2, 2026 | Building Permit Related(MS) | REVISION - add one room in the basement (Booth 015), revise the open waiting room 104 to an enclosed meeting room (Meeting 104) with accessible door added, revise the glazed partition at (Boardroom 105) from an operable partition, to a fixed partition with accessible doors, whereas previous mechanic | — | Open |
| Mar 2, 2026 | Building Permit Related(PS) | REVISION - add one room in the basement (Booth 015), revise the open waiting room 104 to an enclosed meeting room (Meeting 104) with accessible door added, revise the glazed partition at (Boardroom 105) from an operable partition, to a fixed partition with accessible doors, whereas previous mechanic | — | Open |
| Feb 11, 2026 | Sprinklers | Proposal for supply and installation of sprinkler - 4" black steel sch10 sprinkler main on basement level up to and including the 4th floor c/w zone controls on each floor; 2" black steel sch10 sprinkler branch lines on basement level up to and including the 4th floor; 3" black steel sch10 window sp | $152K | Open |
| Dec 3, 2025 | New Building | Revision 02: Proposed pergola structure on suite 503 balcony.Revision 01 - Proposed alteration to an existing Building Permit for the 7th floor and mechanical penthouse layout (21 246313 BLD 00 NB)Interior Altertaions to Ground and second floor suite was added later as part of this revision -------- | — | New build |
| Sep 10, 2025 | Alter: Boiler/Furnace/AC Replacement | Proposal to replace 2 heating boilers. | $200K | Open |
| Aug 13, 2025 | Interior Alterations | Proposal for interior alteration to existing washroom, medical lab and general office space. | $28K | Closed |
| Jul 31, 2025 | Building Permit Related(PS) | Plumbing 01 - Proposed alteration to an existing Building Permit for the 7th floor and mechanical penthouse layout Plumbing - Proposed 7 storey mixed-use building with commercial on ground and 2 levels of underground garage; including a renovation to a re-located existing 2 storey heritage building | — | Open |
| Jul 28, 2025 | Building Permit Related(MS) | HVAC Revision 01 - Proposed alteration to an existing Building Permit for the 7th floor and mechanical penthouse layout (21 246313 BLD 00 NB)-------------------------------------------------------------------------------HVAC - Proposed 7 storey mixed-use building with commercial on ground and 2 leve | — | Open |
| Jun 19, 2025 | Garage Repair/Reconstruction | Proposed garage roof deck waterproofing | $11K | Open |
| May 8, 2025 | Other(BA) | Proposal for Stairwell Guard Alterations | $130K | Open |
| Apr 22, 2025 | Demolition | Proposal to demolish a two storey commercial building to facilitate a new building development of a residential apartment builidng. | — | Demolition |
| Apr 3, 2025 | Re-Roofing/Re-Cladding | Proposed masonry wall replacement at mechanical penthouse | $100K | Closed |
| Feb 4, 2025 | Alternative Solution | The Alternative Solution addresses protection of non-rated frames located between the sprinkler- protected glazed assemblies and adjacent unprotected openings, with closely spaced sprinklers. | — | Closed |
| Jan 24, 2025 | Inside and Outside Drains | Drain - Interior alterations and 4-storey rear addition to existing 3-storey building. | $10.0M | Open |
| Dec 9, 2024 | Electromagnetic Locks | Proposal for installation of one (1) maglock on ground floor. | $1K | Closed |
| Sep 6, 2024 | Building Permit Related(PS) | Plumbing - Proposed interior alterations. | — | Closed |
| Aug 19, 2024 | Interior Alterations | Proposed interior alterations. | $150K | Closed |
| Jun 14, 2024 | Building Permit Related (DR) | Drain - Interior alterations and 4-storey rear addition to existing 3-storey building. | — | Open |
| Apr 8, 2024 | Alternative Solution | Proposed alternative solution to fire seporation for roof top terrace walkable skylight. | — | Closed |
| Mar 26, 2024 | Alternative Solution | Alternative Solution for sprinkler Protected Glazing:Based on the limiting distance 79.74% to 80.69% of the area is required to have a fire resistance rating of not less than 1 h and is proposed to be achieved through sprinkler protected glazing/window sprinklers design in accordance with OBC 3.1.8. | — | Closed |
| Mar 21, 2024 | Building Permit Related(PS) | Plumbing - Proposed interior alterations. | — | Open |
| Mar 21, 2024 | Building Permit Related(MS) | HVAC - Proposed interior alterations. | — | Open |
| Mar 14, 2024 | Interior Alterations | Proposed interior alterations. | $150K | Open |
| Feb 29, 2024 | Alternative Solution | Proposed for all floors to design a standpipe system in a manner that standpipe risers provided with hose connections will be located in exit stairs enclosures or in 1hr rated shafts, if required. No fire hose cabinets will be provided on the floor areas or in the exit stairs. | — | Closed |
| Feb 26, 2024 | Alternative Solution | Alternative Solution for Exiting and Barrier free Access:ExitingThe minimum clear width required for exterior passageway is required to be 1100 mm and OBC 3.4.1.2.(2) highlights that exits are permitted to converge provided the cumulative capacity of converging exits does not contribute more than 50 | — | Open |
| Feb 6, 2024 | Interior Alterations | Interior alterations to an existing residential suite in an existing apartment building - UNIT 1205 | $10K | Open |
| Dec 28, 2023 | Building Permit Related(PS) | Plumbing - Proposal to demolish exitsing offce and reconstruct office to new layout for office purposes. | — | Closed |
| Dec 28, 2023 | Building Permit Related(MS) | HVAC - Proposal to demolish exitsing offce and reconstruct office to new layout for office purposes. | — | Closed |
| Dec 28, 2023 | Interior Alterations | Proposal for interior alterations for a new office fitout for tenant - 'Generation Capital Limited' in this existing ground floor level office. | $1.0M | Open |
| Dec 21, 2023 | Building Permit Related(PS) | Plumbing - Proposal for interior alteration with minor adjustment of HVAC. | — | Closed |
| Nov 21, 2023 | Alternative Solution | It is proposed to address the interconnected openings not more than 20 m2 between second and third floor levels of the building. In addition, it proposes the use of smoke baffles with closely space sprinklers and smoke detection system to address the floor opening in accordance with NFPA 13-2013, 8. | — | Closed |
| Nov 10, 2023 | Building Permit Related(MS) | REV 01 - Revision for an interior alterationHVAC - Proposal for interior alteration with minor adjustment of HVAC. | — | Closed |
| Sep 29, 2023 | Alternative Solution | The 29-31 Prince Arthur Avenue building will be provided with a standpipe system. In lieu of required fire hose stations, it is proposed to install 65 mm fire hose valve connections within the exit stairs in accordance with the NBC and NFPA 14. Fire hose valve connections will be located such that s | — | Closed |
| Aug 23, 2023 | Interior Alterations | Proposal for interior alteration with minor adjustment of HVAC. | $150K | Closed |
| Feb 23, 2023 | Partial Permit - Shoring | Part Permit - Proposed 7 storey mixed-use building with commercial on ground and 2 levels of underground garage; including a renovation to a re-located existing 2 storey heritage building on site. | — | Closed |
| Feb 23, 2023 | Partial Permit - Foundation | Part Permit - Proposed 7 storey mixed-use building with commercial on ground and 2 levels of underground garage; including a renovation to a re-located existing 2 storey heritage building on site. | — | Closed |
| Feb 23, 2023 | Demolition | Revision 01 - Changes to the proposed to be demollition to allow for the relocation of an existing heritage building. demolish existing building for future development | — | Demolition |
| Feb 22, 2023 | Building Permit Related (DR) | Drain - Proposed 7 storey mixed-use building with commercial on ground and 2 levels of underground garage; including a renovation to a re-located existing 2 storey heritage building on site. | — | Open |
The 40 most recent of 213 permits on record. Figures come from the City’s active and cleared permit datasets, refreshed daily — what that covers, and what it misses.